SM-32X16-C5AV-LCD

Video Matrix CAT5 router, 32 in 16 out, RGBHV VGA video + Stereo Audio

CONTROL METHOD

Front Panel Interface
  • Liquid Crystal Display (LCD) can display all current connections.
  • Locally change input and output selections with front panel buttons.
  • Digital VU-Meter displays audio levels for the currently selected port.
  • Configuration and control can be done using the front panel buttons.
  • Main menu allows the user to:
    • Set serial address.
    • Set serial speed.
    • Set IP address.
    • Set Subnet Mask.
    • Adjust contrast.
    • Force compensation.
    • Show size.
RS232 Control
  • Configuration and control can be done through the serial port.
  • Control the switch using the NTI Switch Control Program with Graphical User Interface (GUI control) via RS232.
  • Selectable baud rate: 1200 through 9600.
    • Baud rate is set via the main menu, serial command, telnet or web page.
Commands
  • CS-causes one INx/OUTx connection to occur.
  • CA-causes all inputs to connect to specified output.
  • RO-reads what input is connected to specified output.
  • CC-save matrix.
  • RC-recall matrix.
  • CB-change baud rate.
  • RV-version information.
  • RU-reads size of matrix, reports number of inputs and number of outputs on specified switch.
  • EA-set the IP address.
  • EM-set the IP mask.
  • EG-set the default gateway.
  • ET-set the webserver timeout.
Ethernet Control
  • Configuration can be done over the Internet via web page or telnet.
Web Server (view product demo)
  • Security is ensured by password and user configurable timeout.
  • Up to 25 users can access the web page at one time.
  • The user can access the following pages:
    • Switch page: allows the user to connect any input to any output, save and recall up to ten connections.
    • Administration pages: administrator can access setup pages, port setting page and update firmware page. Assign names to video and audio inputs and outputs.
    • Password page: allows the user to change the password for accessing the web interface.
    • Help page: documentation on the usage of the web interface.
    • Update Web Server page: globally update the web server to any settings that have been changed.
    • Logout page: view currently active connections and logout of the web interface.
Telnet
  • Security is ensured by password.
  • Commands are similar to RS232 commands.
  • The telnet server listens on ports 2000 and 2005.
    • Port 2000 is for an operator telnet session.
    • Port 2005 is intended for a software control type session.
Download Firmware